Percutaneous Tracheostomy Protocol

Purpose

To provide guidance on safe practices to perform percutaneous tracheostomy in the operating room and ICU settings. 

Preprocedural Planning

Equipment

trach 1.png      trach 2.png        trach 3.png

Team

Room Set-up and Patient Positioning

                                                               trach 4.png

                                                     trach 5.png

Technical Steps

  1. Prior to the start of the procedure, a through “timeout” should be performed.  All members of the team should be present and attentive. 
  2. Adequate sedation should be achieved with anxiolytic and narcotic pain medications. This is followed by paralysis.
  3. Palpate the neck to identify relevant anatomy.  Ideal location for placement of the tracheostomy is between the 2nd and 3rd tracheal ring.                                                                                                                                                                                                                                 Trach 6.png
  4. Don all appropriate PPE. Standard sterile surgical technique should be implemented.
  5. Surgically prepare neck and upper chest with chlorohexidine skin prep. Standard sterile technique and draping should be performed.  Consideration for easy access to the endotracheal tube to allow for easy airway exchange after trach is placed.  
  6. Anesthetize the skin and subcutaneous tissue with local anesthetic.                                                                                                                                                  Trach 7.png
  7. Using a #15 scalpel, make a 2-3 cm vertical, midline incision approximately 40 mm cephalad (1-2 finger breaths) to the sternal notch and just below the cricoid cartilage. If an anterior jugular vein is encountered in the incision (even if no injury is suspected), consider ligation proximally and distally as this is easiest to perform before the tracheostomy tube has been placed.                                                                                                                                                                                                                   trach 8.png
  8. Using a hemostat, bluntly dissect the subcutaneous tissue and muscle in midline to the pretracheal tissue along the length of the incision to better palpate the trachea to determine the point of entry.
  9. With the bronchoscope adaptor in place, advance the bronchoscope into the airway.  Inspect the trachea and bronchial trees and clear any secretions. 
  10. With the assistance of the respiratory therapist, while keeping the bronchoscope at the end of the endotracheal tube, retract both the endotracheal tube and bronchoscope simultaneously until the subglottic structures are visualized and one can see the anterior wall of trachea being palpated by the surgeon.  The bronchoscope should be always kept within the endotracheal tube during this portion of the procedure in order to maintain control of the airway and ensure that the bronchoscope is not damaged.
  11. ***Although usually unnecessary, cautery may be used prior to entering the trachea with the introducer needle.  After entry into the trachea, cautery should not be used do to the risk of fire with open oxygen source.***
  12. An introducer needle is used the enter the anterior portion of the trachea between the 2nd and 3rd tracheal ring (approximately 1 finger breadth below the cricoid cartilage). With the bevel of the needle facing downward, the guidewire is passed into the trachea. Visualization of the guide wire going in the direction of the carina is required. Advance the guidewire slightly passed the carina into the right or left mainstem bronchus.                                                                          trach 9.png     trach 10.png         trach 11.png
  13. Using the Seldinger technique, with constant Bronchoscopic visualization and control of the wire within the trachea, the trachea is sequentially dilated. The dilator handle is hydrophobic which makes it less likely to slip in a wet environment while the actual dilating portion is hydrophilic which only requires water/liquid to be lubricated.  First the small tracheal dilator is advanced over the wire to dilate the pretracheal tract. Next the single-stage tapered dilator and the guiding catheter are advanced as a unit over the wire to dilate the trachea. Markings on the side of the progressive dilators guide the depth to which they are inserted.  All catheters (pretracheal dilator, tapered dilator, and guiding catheter) should enter perpendicular to the trachea as to prevent pretracheal dissection or false passage.  If the patient has limited ventilatory reserve prior to the procedure, the bronchoscope can be removed prior to the dilation portion of the procedure.                                                                                                                                                                                                            trach 12.png  trach 13.png                                                     trach 14.png  trach 15.png
  14. The tapered dilator is removed from the guiding catheter and the guidewire, leaving the guiding catheter and the guidewire in place.  If there is a longer distance between the tracheal surface and the skin surface, a finger can be used to dilatate the tract to help facilitate placement of the tracheostomy during the next step.
  15. Next, an appropriately sized and well lubricated tracheostomy tube with introducer is advanced over the wire and guiding catheter into the trachea. The wire, guiding catheter and loading trocar is then removed, keeping the tracheostomy in place.                                                                                                                                                                               trach 16.png  trach 17.png
  16. Inflate the tracheostomy cuff, insert the inner canula and connect tracheostomy to ventilator circuit. The presence of end-tidal carbon dioxide after ventilation resumes confirms placement in the airway.
  17. A bronchoscopy should be performed through the newly placed tracheostomy to visually confirm that it is within the trachea in proper position. Only remove ET tube after placement of tracheostomy tube within the trachea is confirmed.
  18. The tracheostomy is secured with a tracheostomy collar or ties to help prevent accidental dislodgement and provide time for adequate to tract formation. 
  19. Obtain a chest x-ray to confirm appropriate positioning of the tracheostomy tube, rule out pneumothorax, and evaluate for bronchial obstruction.

Tracheostomy Care

Key Contributors

Bennett Berning, MD

Last Updated

March, 2023

References

  1. Cheung NH, Napolitano LM. Tracheostomy: epidemiology, indications, timing, technique, and outcomes. Respir Care. 2014 Jun;59(6):895-915; discussion 916-9.
  2. Young D, Harrison DA, Cuthbertson BH, Rowan K, TracMan Col- laborators. Effect of early vs late tracheostomy placement on survival in patients receiving mechanical ventilation: the TracMan randomized trial. JAMA 2013;309(20):2121-2129.
  3. Holevar M, Dunham JC, Brautigan R, Clancy TV, Como JJ, Ebert JB, Griffen MM, Hoff WS, Kurek SJ Jr, Talbert SM, Tisherman SA. Practice management guidelines for timing of tracheostomy: the EAST Practice Management Guidelines Work Group. J Trauma. 2009 Oct;67(4):870-4.
  4. Delaney A, Bagshaw SM, Nalos M. Percutaneous dilatational tracheostomy versus surgical tracheostomy in critically ill patients: a systematic review and meta-analysis. Crit Care 2006;10(2):R55.
  5. Hashimoto DA, Axtell AL, Auchincloss HG. Percutaneous Tracheostomy. N Engl J Med. 2020 Nov 12;383(20):e112.
  6. Hawn, M. T., Berning, B. J., & de Moya, M. A. (2023). Tracheostomy: Open and Percutaneous. In Operative techniques in surgery (2nd Edition, Vol. Volume Two, pp. 2506–2512). Wolters Kluwer. 



 


Revision #1
Created 18 May 2023 19:03:08 by Emily Cantrell
Updated 12 February 2026 15:49:40 by Emily Cantrell